new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 23

MedQARo: A Large-Scale Benchmark for Medical Question Answering in Romanian

Question answering (QA) is an actively studied topic, being a core natural language processing (NLP) task that needs to be addressed before achieving Artificial General Intelligence (AGI). However, the lack of QA datasets in specific domains and languages hinders the development of robust AI models able to generalize across various domains and languages. To this end, we introduce MedQARo, the first large-scale medical QA benchmark in Romanian, alongside a comprehensive evaluation of state-of-the-art large language models (LLMs). We construct a high-quality and large-scale dataset comprising 102,646 QA pairs related to cancer patients. The questions regard medical case summaries of 1,011 patients, requiring either keyword extraction or reasoning to be answered correctly. MedQARo is the result of a time-consuming manual annotation process carried out by seven physicians specialized in oncology or radiotherapy, who spent a total of about 2,100 work hours to generate the QA pairs. We experiment with four LLMs from distinct families of models on MedQARo. Each model is employed in two scenarios, namely one based on zero-shot prompting and one based on supervised fine-tuning. Our results show that fine-tuned models significantly outperform their zero-shot counterparts, clearly indicating that pretrained models fail to generalize on MedQARo. Our findings demonstrate the importance of both domain-specific and language-specific fine-tuning for reliable clinical QA in Romanian. We publicly release our dataset and code at https://github.com/ana-rogoz/MedQARo.

  • 6 authors
·
Aug 22, 2025

LLM-MedQA: Enhancing Medical Question Answering through Case Studies in Large Language Models

Accurate and efficient question-answering systems are essential for delivering high-quality patient care in the medical field. While Large Language Models (LLMs) have made remarkable strides across various domains, they continue to face significant challenges in medical question answering, particularly in understanding domain-specific terminologies and performing complex reasoning. These limitations undermine their effectiveness in critical medical applications. To address these issues, we propose a novel approach incorporating similar case generation within a multi-agent medical question-answering (MedQA) system. Specifically, we leverage the Llama3.1:70B model, a state-of-the-art LLM, in a multi-agent architecture to enhance performance on the MedQA dataset using zero-shot learning. Our method capitalizes on the model's inherent medical knowledge and reasoning capabilities, eliminating the need for additional training data. Experimental results show substantial performance gains over existing benchmark models, with improvements of 7% in both accuracy and F1-score across various medical QA tasks. Furthermore, we examine the model's interpretability and reliability in addressing complex medical queries. This research not only offers a robust solution for medical question answering but also establishes a foundation for broader applications of LLMs in the medical domain.

  • 9 authors
·
Dec 31, 2024

Labadain-MedQA: A Tetun Medical QA Dataset for Fine-Tuning and Evaluating Large Language Models

Advances in large language models (LLMs) have created opportunities for cross-lingual transfer of medical knowledge from high-resource to low-resource languages to support access to healthcare information. However, medical question-answering (QA) datasets for fine-tuning and evaluating LLMs remain scarce for Tetun. To address this gap, we translated MedAlpaca's Medical Flashcards and WikiDoc Patient Information collections into Tetun using Gemini 2.5 Flash, producing 39,077 medical QA pairs. Translation quality was assessed on 50 randomly sampled QA pairs (100 documents) using automatic metrics against human reference translations and evaluations by two native Tetun-speaking healthcare professionals, focusing on medical accuracy and Tetun fluency. Human translations achieved higher mean ratings than LLM-generated translations for both criteria (4.43/5 vs. 4.02/5), with statistically significant differences (Wilcoxon signed-rank test, p < 0.001). To assess downstream utility, we fine-tuned Gemma and Llama variants on the translated MedAlpaca dataset using parameter-efficient fine-tuning (PEFT) and evaluated them on 325 Tetun-translated United States Medical Licensing Examination multiple-choice questions. Gemma 4 12B fine-tuned using QLoRA achieved relative improvements in mean accuracy of 10.79% with 4-bit NormalFloat (NF4) inference and 10.42% after merging the LoRA adapters into the BF16 base model, compared with the corresponding base models. These results highlight the viability of automatic dataset translation for Tetun medical QA and the effectiveness of PEFT in enhancing model performance. The datasets, models, and evaluation resources are accessible at https://github.com/labadain/labadain-medqa to support reproducible research on Tetun medical QA and facilitate machine translation, cross lingual, and multilingual research.

  • 2 authors
·
Oct 30

Shallow Robustness, Deep Vulnerabilities: Multi-Turn Evaluation of Medical LLMs

Large language models (LLMs) are rapidly transitioning into medical clinical use, yet their reliability under realistic, multi-turn interactions remains poorly understood. Existing evaluation frameworks typically assess single-turn question answering under idealized conditions, overlooking the complexities of medical consultations where conflicting input, misleading context, and authority influence are common. We introduce MedQA-Followup, a framework for systematically evaluating multi-turn robustness in medical question answering. Our approach distinguishes between shallow robustness (resisting misleading initial context) and deep robustness (maintaining accuracy when answers are challenged across turns), while also introducing an indirect-direct axis that separates contextual framing (indirect) from explicit suggestion (direct). Using controlled interventions on the MedQA dataset, we evaluate five state-of-the-art LLMs and find that while models perform reasonably well under shallow perturbations, they exhibit severe vulnerabilities in multi-turn settings, with accuracy dropping from 91.2% to as low as 13.5% for Claude Sonnet 4. Counterintuitively, indirect, context-based interventions are often more harmful than direct suggestions, yielding larger accuracy drops across models and exposing a significant vulnerability for clinical deployment. Further compounding analyses reveal model differences, with some showing additional performance drops under repeated interventions while others partially recovering or even improving. These findings highlight multi-turn robustness as a critical but underexplored dimension for safe and reliable deployment of medical LLMs.

  • 5 authors
·
Oct 14, 2025

Capabilities of Gemini Models in Medicine

Excellence in a wide variety of medical applications poses considerable challenges for AI, requiring advanced reasoning, access to up-to-date medical knowledge and understanding of complex multimodal data. Gemini models, with strong general capabilities in multimodal and long-context reasoning, offer exciting possibilities in medicine. Building on these core strengths of Gemini, we introduce Med-Gemini, a family of highly capable multimodal models that are specialized in medicine with the ability to seamlessly use web search, and that can be efficiently tailored to novel modalities using custom encoders. We evaluate Med-Gemini on 14 medical benchmarks, establishing new state-of-the-art (SoTA) performance on 10 of them, and surpass the GPT-4 model family on every benchmark where a direct comparison is viable, often by a wide margin. On the popular MedQA (USMLE) benchmark, our best-performing Med-Gemini model achieves SoTA performance of 91.1% accuracy, using a novel uncertainty-guided search strategy. On 7 multimodal benchmarks including NEJM Image Challenges and MMMU (health & medicine), Med-Gemini improves over GPT-4V by an average relative margin of 44.5%. We demonstrate the effectiveness of Med-Gemini's long-context capabilities through SoTA performance on a needle-in-a-haystack retrieval task from long de-identified health records and medical video question answering, surpassing prior bespoke methods using only in-context learning. Finally, Med-Gemini's performance suggests real-world utility by surpassing human experts on tasks such as medical text summarization, alongside demonstrations of promising potential for multimodal medical dialogue, medical research and education. Taken together, our results offer compelling evidence for Med-Gemini's potential, although further rigorous evaluation will be crucial before real-world deployment in this safety-critical domain.

  • 66 authors
·
Apr 29, 2024 3

Susceptibility of Large Language Models to User-Driven Factors in Medical Queries

Large language models (LLMs) are increasingly used in healthcare, but their reliability is heavily influenced by user-driven factors such as question phrasing and the completeness of clinical information. In this study, we examined how misinformation framing, source authority, model persona, and omission of key clinical details affect the diagnostic accuracy and reliability of LLM outputs. We conducted two experiments: one introducing misleading external opinions with varying assertiveness (perturbation test), and another removing specific categories of patient information (ablation test). Using public datasets (MedQA and Medbullets), we evaluated proprietary models (GPT-4o, Claude 3.5 Sonnet, Claude 3.5 Haiku, Gemini 1.5 Pro, Gemini 1.5 Flash) and open-source models (LLaMA 3 8B, LLaMA 3 Med42 8B, DeepSeek R1 8B). All models were vulnerable to user-driven misinformation, with proprietary models especially affected by definitive and authoritative language. Assertive tone had the greatest negative impact on accuracy. In the ablation test, omitting physical exam findings and lab results caused the most significant performance drop. Although proprietary models had higher baseline accuracy, their performance declined sharply under misinformation. These results highlight the need for well-structured prompts and complete clinical context. Users should avoid authoritative framing of misinformation and provide full clinical details, especially for complex cases.

  • 7 authors
·
Mar 26, 2025

Med-REFL: Medical Reasoning Enhancement via Self-Corrected Fine-grained Reflection

Large reasoning models have recently made significant strides in mathematical and code reasoning, yet their success has not transferred smoothly to the medical domain. While multiple factors contribute to this disparity, a critical issue is the inadequate focus on the quality of intermediate reflection steps, which is particularly crucial in high-stakes medical scenarios. To address this challenge, we propose Med-REFL, a \textbf{Med}ical \textbf{R}easoning \textbf{E}nhancement via self-corrected \textbf{F}ine-grained ref\textbf{L}ection. Our method leverages a tree-of-thought approach to decompose medical questions into fine-grained reasoning paths, quantitatively evaluating each step and its subsequent reflections. These assessments enable automatic construction of direct preference optimization data, reducing reliance on expensive expert annotations while guiding models to identify and correct reasoning errors. Experimental results on the MedQA-USMLE benchmark demonstrate Med-REFL achieves consistent improvements, with average gains up to 4.11\%. Notably, it further boosts the state-of-the-art performance of 7B/8B models by an additional 4.13\%. Furthermore, Med-REFL exhibits strong generalization capabilities and robustness across several challenging medical question-answering datasets. Our work illustrates that prioritizing reflection quality leads to more accurate and trustworthy reasoning in medical AI applications. Checkpoints, code, and data can be found https://github.com/TianYin123/Med-REFL{here}.

  • 5 authors
·
Jun 11, 2025 1

Beyond Benchmarks: Dynamic, Automatic And Systematic Red-Teaming Agents For Trustworthy Medical Language Models

Ensuring the safety and reliability of large language models (LLMs) in clinical practice is critical to prevent patient harm and promote trustworthy healthcare applications of AI. However, LLMs are advancing so rapidly that static safety benchmarks often become obsolete upon publication, yielding only an incomplete and sometimes misleading picture of model trustworthiness. We demonstrate that a Dynamic, Automatic, and Systematic (DAS) red-teaming framework that continuously stress-tests LLMs can reveal significant weaknesses of current LLMs across four safety-critical domains: robustness, privacy, bias/fairness, and hallucination. A suite of adversarial agents is applied to autonomously mutate test cases, identify/evolve unsafe-triggering strategies, and evaluate responses, uncovering vulnerabilities in real time without human intervention. Applying DAS to 15 proprietary and open-source LLMs revealed a stark contrast between static benchmark performance and vulnerability under adversarial pressure. Despite a median MedQA accuracy exceeding 80\%, 94\% of previously correct answers failed our dynamic robustness tests. We observed similarly high failure rates across other domains: privacy leaks were elicited in 86\% of scenarios, cognitive-bias priming altered clinical recommendations in 81\% of fairness tests, and we identified hallucination rates exceeding 66\% in widely used models. Such profound residual risks are incompatible with routine clinical practice. By converting red-teaming from a static checklist into a dynamic stress-test audit, DAS red-teaming offers the surveillance that hospitals/regulators/technology vendors require as LLMs become embedded in patient chatbots, decision-support dashboards, and broader healthcare workflows. Our framework delivers an evolvable, scalable, and reliable safeguard for the next generation of medical AI.

  • 21 authors
·
Jul 30, 2025

The Effect of Quantization on Clinical Benchmarks: Accuracy and Safety Across Model Families

Quantization enables deployment of large language models on resource-constrained clinical edge devices, but its effect on clinical accuracy and safety remains understudied. We evaluate five 7-8B parameter models at FP16, GPTQ-INT8, and GPTQ-INT4 precision across five benchmarks: MedQA, MedMCQA, Med-HALT, a risk-stratified sample of HealthBench, and MedSafetyBench. The study jointly varies quantization bit width, model family, and clinical task type, with explicit risk stratification and safety measures. INT8 GPTQ is universally safe (max. degradation -1.9%-1.9%), while INT4 degradation is substantial and model-dependent: BioMistral-7B, clinically fine-tuned, loses 19.7% on MedMCQA, more than any general-purpose model, showing clinical fine-tuning does not confer compression robustness. MedMCQA degrades more than MedQA under INT4; Med-HALT is largely unaffected. On HealthBench's emergency-risk subgroup, Qwen2.5-7B degrades by 26.8% under INT4, suggesting high-risk scenarios are disproportionately vulnerable to compression. On MedSafetyBench, the model family dominates over precision (refusal rates range 10.2%-74.9% at FP16), though Qwen2.5-7B (-17.8%) and Meditron-7B (-28.3%) show substantial INT4 safety degradation; notably, Qwen2.5-7B is simultaneously the most accuracy-robust model, demonstrating that accuracy and safety robustness are independent properties. We additionally test two recovery methods, clinical calibration substitution and QLoRA fine-tuning, both producing the same trade-off: MedMCQA recovers while MedQA further degrades, indicating recovery strategies require task-specific validation rather than being assumed universally beneficial. These findings indicate INT8 is broadly safe for clinical deployment, while INT4 safety must be assessed per-model and per-task, and that safety alignment is determined primarily by instruction tuning rather than clinical domain adaptation.

  • 2 authors
·
Sep 1

DERA: Enhancing Large Language Model Completions with Dialog-Enabled Resolving Agents

Large language models (LLMs) have emerged as valuable tools for many natural language understanding tasks. In safety-critical applications such as healthcare, the utility of these models is governed by their ability to generate outputs that are factually accurate and complete. In this work, we present dialog-enabled resolving agents (DERA). DERA is a paradigm made possible by the increased conversational abilities of LLMs, namely GPT-4. It provides a simple, interpretable forum for models to communicate feedback and iteratively improve output. We frame our dialog as a discussion between two agent types - a Researcher, who processes information and identifies crucial problem components, and a Decider, who has the autonomy to integrate the Researcher's information and makes judgments on the final output. We test DERA against three clinically-focused tasks. For medical conversation summarization and care plan generation, DERA shows significant improvement over the base GPT-4 performance in both human expert preference evaluations and quantitative metrics. In a new finding, we also show that GPT-4's performance (70%) on an open-ended version of the MedQA question-answering (QA) dataset (Jin et al. 2021, USMLE) is well above the passing level (60%), with DERA showing similar performance. We release the open-ended MEDQA dataset at https://github.com/curai/curai-research/tree/main/DERA.

  • 4 authors
·
Mar 29, 2023

Citrus: Leveraging Expert Cognitive Pathways in a Medical Language Model for Advanced Medical Decision Support

Large language models (LLMs), particularly those with reasoning capabilities, have rapidly advanced in recent years, demonstrating significant potential across a wide range of applications. However, their deployment in healthcare, especially in disease reasoning tasks, is hindered by the challenge of acquiring expert-level cognitive data. In this paper, we introduce Citrus, a medical language model that bridges the gap between clinical expertise and AI reasoning by emulating the cognitive processes of medical experts. The model is trained on a large corpus of simulated expert disease reasoning data, synthesized using a novel approach that accurately captures the decision-making pathways of clinicians. This approach enables Citrus to better simulate the complex reasoning processes involved in diagnosing and treating medical conditions.To further address the lack of publicly available datasets for medical reasoning tasks, we release the last-stage training data, including a custom-built medical diagnostic dialogue dataset. This open-source contribution aims to support further research and development in the field. Evaluations using authoritative benchmarks such as MedQA, covering tasks in medical reasoning and language understanding, show that Citrus achieves superior performance compared to other models of similar size. These results highlight Citrus potential to significantly enhance medical decision support systems, providing a more accurate and efficient tool for clinical decision-making.

  • 12 authors
·
Feb 25, 2025

MedCaseReasoning: Evaluating and learning diagnostic reasoning from clinical case reports

Doctors and patients alike increasingly use Large Language Models (LLMs) to diagnose clinical cases. However, unlike domains such as math or coding, where correctness can be objectively defined by the final answer, medical diagnosis requires both the outcome and the reasoning process to be accurate. Currently, widely used medical benchmarks like MedQA and MMLU assess only accuracy in the final answer, overlooking the quality and faithfulness of the clinical reasoning process. To address this limitation, we introduce MedCaseReasoning, the first open-access dataset for evaluating LLMs on their ability to align with clinician-authored diagnostic reasoning. The dataset includes 14,489 diagnostic question-and-answer cases, each paired with detailed reasoning statements derived from open-access medical case reports. We evaluate state-of-the-art reasoning LLMs on MedCaseReasoning and find significant shortcomings in their diagnoses and reasoning: for instance, the top-performing open-source model, DeepSeek-R1, achieves only 48% 10-shot diagnostic accuracy and mentions only 64% of the clinician reasoning statements (recall). However, we demonstrate that fine-tuning LLMs on the reasoning traces derived from MedCaseReasoning significantly improves diagnostic accuracy and clinical reasoning recall by an average relative gain of 29% and 41%, respectively. The open-source dataset, code, and models are available at https://github.com/kevinwu23/Stanford-MedCaseReasoning.

  • 10 authors
·
May 16, 2025 2

Compared to What? Baselines and Metrics for Counterfactual Prompting

Counterfactual prompting (i.e., perturbing a single factor and measuring output change) is widely used to evaluate things like LLM bias and CoT faithfulness. But in this work we argue that observed effects cannot be attributed to the targeted factor without accounting for baseline ``meaning-preserving'' modifications to text that establish general model sensitivity. This is because every counterfactual edit is a compound treatment that bundles the variable of interest with incidental surface-form variation; this violates treatment variation irrelevance. We observe prediction flip rates on MedQA of 14.9% when we surgically change patient gender. However, this is statistically indistinguishable from the flip rates induced by simply paraphrasing inputs (14.1%). In this case, it would therefore be unwarranted to conclude that the LLM is especially sensitive to patient gender. To account for this and robustly measure the effects of targeted interventions, we propose a framework in which we compare (via statistical testing) differences observed under target interventions to those induced by paraphrasing inputs. We then use this framework to revisit a analysis done on the MedPerturb dataset, which reported evidence of model sensitivity to patient demographics and stylistic cues. We find that these effects largely dissipate when we account for general model sensitivity, with only 5 of 120 tests reaching statistical significance. Applying the same framework to occupational biography classification, we detect clearly significant directional gender bias, showing that the framework identifies real directional effects even when they are small. We evaluate a range of metrics -- aggregate, per-sample distributional, and regression -- and find that per-sample metrics are dramatically more powerful than aggregate metrics and regression powerfully and uniquely characterizes effect direction and magnitude.

  • 4 authors
·
Apr 30

MedJev: Evaluating Zero-Shot System-One Decision Making in Medicine

System One decision models such as Jev answer structured questions in a single forward pass without generating text, offering fast and computationally efficient clinical decision support. We evaluate MedJev, an open System One model that runs locally on a laptop, across ten medical benchmarks spanning medical knowledge, diagnosis, and patient level prediction using MIMIC IV and MIMIC IV ED. We compare MedJev against zero shot LLM baselines, published GPT results, and supervised models. MedJev achieves accuracies of 72.5 percent on MedQA, 75.4 percent on USMLE, and 80.1 percent on NEJM, approaching published GPT 4 performance while maintaining well calibrated confidence estimates (ECE 0.028 to 0.063). On patient level tasks, MedJev achieves an AUROC of 0.926 for In Hospital Mortality, exceeding XGBoost (0.902), but underperforms supervised models on operational outcomes such as ED Triage Admission (0.745 vs. 0.809). Patient level predictions also exhibit substantial miscalibration (In Hospital Mortality ECE 0.286). We introduce a lightweight, two parameter recalibration method that adapts predictions to local patient populations using 50 to 200 labeled examples, reducing ECE to 0.007. Our findings establish open System One models as a promising zero shot baseline for medical AI, combining competitive predictive performance with low computational cost and efficient local calibration. We release our code and evaluation harness to support future research.

  • 5 authors
·
Oct 25

Towards Expert-Level Medical Question Answering with Large Language Models

Recent artificial intelligence (AI) systems have reached milestones in "grand challenges" ranging from Go to protein-folding. The capability to retrieve medical knowledge, reason over it, and answer medical questions comparably to physicians has long been viewed as one such grand challenge. Large language models (LLMs) have catalyzed significant progress in medical question answering; Med-PaLM was the first model to exceed a "passing" score in US Medical Licensing Examination (USMLE) style questions with a score of 67.2% on the MedQA dataset. However, this and other prior work suggested significant room for improvement, especially when models' answers were compared to clinicians' answers. Here we present Med-PaLM 2, which bridges these gaps by leveraging a combination of base LLM improvements (PaLM 2), medical domain finetuning, and prompting strategies including a novel ensemble refinement approach. Med-PaLM 2 scored up to 86.5% on the MedQA dataset, improving upon Med-PaLM by over 19% and setting a new state-of-the-art. We also observed performance approaching or exceeding state-of-the-art across MedMCQA, PubMedQA, and MMLU clinical topics datasets. We performed detailed human evaluations on long-form questions along multiple axes relevant to clinical applications. In pairwise comparative ranking of 1066 consumer medical questions, physicians preferred Med-PaLM 2 answers to those produced by physicians on eight of nine axes pertaining to clinical utility (p < 0.001). We also observed significant improvements compared to Med-PaLM on every evaluation axis (p < 0.001) on newly introduced datasets of 240 long-form "adversarial" questions to probe LLM limitations. While further studies are necessary to validate the efficacy of these models in real-world settings, these results highlight rapid progress towards physician-level performance in medical question answering.

  • 31 authors
·
May 16, 2023 2

OpenMedLM: Prompt engineering can out-perform fine-tuning in medical question-answering with open-source large language models

LLMs have become increasingly capable at accomplishing a range of specialized-tasks and can be utilized to expand equitable access to medical knowledge. Most medical LLMs have involved extensive fine-tuning, leveraging specialized medical data and significant, thus costly, amounts of computational power. Many of the top performing LLMs are proprietary and their access is limited to very few research groups. However, open-source (OS) models represent a key area of growth for medical LLMs due to significant improvements in performance and an inherent ability to provide the transparency and compliance required in healthcare. We present OpenMedLM, a prompting platform which delivers state-of-the-art (SOTA) performance for OS LLMs on medical benchmarks. We evaluated a range of OS foundation LLMs (7B-70B) on four medical benchmarks (MedQA, MedMCQA, PubMedQA, MMLU medical-subset). We employed a series of prompting strategies, including zero-shot, few-shot, chain-of-thought (random selection and kNN selection), and ensemble/self-consistency voting. We found that OpenMedLM delivers OS SOTA results on three common medical LLM benchmarks, surpassing the previous best performing OS models that leveraged computationally costly extensive fine-tuning. The model delivers a 72.6% accuracy on the MedQA benchmark, outperforming the previous SOTA by 2.4%, and achieves 81.7% accuracy on the MMLU medical-subset, establishing itself as the first OS LLM to surpass 80% accuracy on this benchmark. Our results highlight medical-specific emergent properties in OS LLMs which have not yet been documented to date elsewhere, and showcase the benefits of further leveraging prompt engineering to improve the performance of accessible LLMs for medical applications.

  • 10 authors
·
Feb 29, 2024

Agents Catching Agents: Shortcut Cascades and Benchmark Gaming in Clinical Multi-Agent Systems

Clinical decision support is moving toward committees of language-model agents deliberating on a shared workspace. We ask whether such committees can be gamed by shortcuts, cues a benchmark rewards but a clinician would ignore. Across seven cohorts on six public datasets spanning text (MedQA-USMLE, MedMCQA, MIMIC-CXR reports), imaging (NIH ChestX-ray14, MIMIC-CXR-JPG, CheXpert) and tabular ICU records (SUPPORT2), Gemini committees resist these cues in isolation (flip 5-16%), yet a socially plausible shortcut spreads: when two peers assert the same wrong answer, the holdout under test adopts it in 38% of cases, as does a false "pre-screen" system flag, on both capability tiers. Of three oversight agents, a gate cannot separate adoption from honest agreement (false-positive rate 100%); a same-lineage judge reading only the transcript flags adoption on text (precision 100%, recall 93%) but collapses onto the gate in imaging; a referee that privately re-queries the holdout transfers to imaging (77-88% precision, 13-21% false-positive rate). Tripling a cue's visual salience does not move contagion, whereas a second peer voice raises it by half again. Gaming a hidden rubric is near-silent: only 1/10 text and 1/134 imaging drifters name the rubric they moved toward. What games a committee is social plausibility, and only a referee independent of self-report catches it. Code: https://github.com/criticaldata/benchmaxxing